Scientific Production Faculty

Trends on the Development of Non-Enzymatic Electrochemical Sensors Modified with Metal-Oxide Nanostructures for the Quantification of Uric Acid



Alvarez Romero, Giaan Arturo

2021

D. Hernández-Ramírez, l . H. Mendoza-Huizar., C. A. Galán-Vidal, G.Y. Aguilar-Lira, and G.A. Álvarez-Romero. Review?Trends on the Development of Non-Enzymatic Electrochemical Sensors Modified with Metal-Oxide Nanostructures for the Quantification of Uric Acid. 2021 J. Electrochem. Soc. 168, 057522


Abstract


Uric acid is one of the most important metabolites as its blood levels can help to diagnose important diseases. Tradicionally, uric acid is determined by enzymatic-spectrophotometric techniques, but in recent years new promising alternatives have arisen. This review is devoted to the development over the past decade of non-enzymatic electrochemical studies based on nano-structures of non-noble metal oxides (Fe2O3, CuO, Cu2O, ZnO, NiO, MnO2, CeO2, MgO, SnO2 and Co3O4) for uric acid detection. The proposals showed the application of electrochemical sensors for the determination of uric acid in blood, urine, pharmaceuticals, water, and commercial shellfish. The developed electrodes are based on vitreous carbon electrodes, carbon paste, or screen-printed, mainly modified with nano-structures of metal oxides to electrochemically oxidize uric acid, where the anodic current peak is used as the analytical signal and the results reported are very promising.






Related articles

Development of a novel composite sensor based on doped pyrrole selective to nitrate ions

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Synthesis and crystal structures of cis-palladium(II) and cis-platinum(II) complexes containing dipy...

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5)-(tris(3,5...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...