Scientific Production Faculty

Large?volume sample stacking with polarity switching for analysis of azo dyes in water samples by capillary electrophoresis



Rodríguez Ávila, José Antonio

2019

J. Francisco Flores-Aguilar, Lorena C. Medrano, Emmanuel Perez-Escalante, Jose A. Rodriguez, Rosa L. Camacho-Mendoza & Israel S. Ibarra (2019) Large?volume sample stacking with polarity switching for analysis of azo dyes in water samples by capillary electrophoresis, International Journal of Environmental Analytical Chemistry, 99:13, 1255-1267, DOI: 10.1080/03067319.2019.1618461


Abstract


A simple, fast and efficient on-line pre-concentration method (large-volume sample stacking) by capillary electrophoresis was proposed for determination of azo dyes residues (allura red [AR], sunset yellow [SY] and tartrazine [TAR]) in water samples. Pre-concentration variables involved in the system were optimised using of a Box?Bhenken design. Under the optimal conditions: injection time 150.0 s, pre-concentration time 120.0 s and reverse potential ?8.0 kV, the proposed methodology improved the analytical sensibility achieving limits of detection of 21.0?41.4 g L?1 with enrichment factors of 82.1?210.8 fold. The large-volume sample stacking-capillary electrophoresis method was validated and applied to determine azo dyes residues in 20 water samples (bottled, spring and tap water). Two samples were positive for sunset yellow and tartrazine with a concentration of 25.3 and 30.2 g L?1 and % RSD less than 10.0% in all cases.



Research Product




Related articles

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Potentiometric Behavior of Diverse Polypyrrole-sulphate Films Electro Synthesized on Graphite - Epox...

Development of a novel nitrate-selective composite sensor based on doped polypyrrole

Facilitated transport of Hg(II) through novel activated composite membranes

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Renewable stationary phase liquid magnetochromatography: determining aspartame and its hydrolysis pr...

Metal content evaluation and its effect on the stability of anthocyanins

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Synthesis and crystal structures of cis-palladium(II) and cis-platinum(II) complexes containing dipy...