Scientific Production Faculty

Removal and confinement of Hg(II) by polyurethane foam functionalized with potassium O-ethyldithiocarbonate



Páez Hernández, María Elena

2019

Flores-Aguilar, J.F., Galán-Vidal, C.A., Rodríguez, J.A., Alvarado-Rodríguez, J.G., Páez-Hernández, M.E., Removal and confinement of Hg(II) by polyurethane foam functionalized with potassium O-ethyldithiocarbonate. International Journal of Environmental Science and Technology, 16 ( 2, 4) 2019, 1005-1014. https://doi.org/10.1007/s1376


Abstract


Polyurethane foam functionalized with potassium O-ethyldithiocarbonate was evaluated as an extractant material for Hg(II). Several parameters such as pH, mass amount and extraction time were studied. Under the best conditions, a 86% of mercury extraction was achieved. Dubinin?Radushkevich isotherm model indicated that the nature of interaction between functionalized foam and Hg(II) is chemical. Regarding interferents, metallic ions Ag(I) and Sn(IV) have a significant influence on the Hg extraction percentage. In the case of silver, it had a synergistic effect increasing the percentage of mercury due to a metallophilic interaction. Also, once the mercury was extracted, its leaching from the functionalized polyurethane foam was evaluated by means of two sequential extraction procedures. In this way, the functionalized foam emerges as a good material for the removal and confinement of chemical species. Obtained results show that mercury extraction is successful even from complex solution and that mercury-foam material is stable under extreme chemical and temperature conditions.



Research Product




Related articles

Influence of the Cation Nature of the Sulphate Salt on the Electrochemical Synthesis of Sulfate-Dope...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

High-performance liquid magneto-chromatography

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Facilitated transport of Hg(II) through novel activated composite membranes

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Study of the Humic Acid-Heavy Metal Interactions and Determination of their Stability Constants....

Determination of primary amino acids in wines by high performance liquid magneto-chromatography

Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determinatio...