Scientific Production Faculty

New Poly(Ionic Liquid) Based Fiber for Determination of Oxytetracycline in Milk Samples by Application of SPME-CE Technique



Rodríguez Ávila, José Antonio

2019

Ferreira, TA., Flores-Aguilar, JF.,Santos, EM., Rodriguez, JA., Ibarra, IS., New Poly(Ionic Liquid) Based Fiber for Determination of Oxytetracycline in Milk Samples by Application of SPME-CE Technique. MOLECULES, 2019, 24(3), 430DOI: 10.3390/molecules2403030430.


Abstract


In this work, a procedure using solid phase microextraction in combination with capillary electrophoresis was developed for the determination of oxytetracycline in milk samples. The method involves the synthesis of poly(1-allyl-3-methyl imidazolium) chloride film on a stainless-steel bar via electropolymerization and its use as an adsorbent for oxytetracycline (OT) by an ionic exchange mechanism. The coated fiber is then immersed in milk samples for retention of oxytetracycline residues, followed by elution, drying, and reconstitution before analysis with capillary electrophoresis. The proposed method achieves a limit of detection of 70 g L?1 with adequate precision and uncertainty, making this methodology appropriate for the determination of OT in milk samples. The method was applied to the pre-concentration and quantification of oxytetracycline in ten commercial milk samples. Two tested samples were positive for the presence of oxytetracycline but the concentration was below the maximum residue limit according to the international normative standard. The proposed methodology was evaluated according to the Eco-Scale approach, and the total score of 51 indicated that the proposed methodology is both green and acceptable despite the multi-stage character. SPME-CE methodology allows us to perform the sample pre-treatment and determination of OT in an effective and greener way, decreasing the number of steps during the analysis and the generation of waste.



Research Product




Related articles

Study of the Humic Acid-Heavy Metal Interactions and Determination of their Stability Constants....

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Evaluation of metal content and its effect on the stability of anthocyanins

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Magnetic solids in analytical chemistry: A review

Chemical studies of anthocyanins: A review

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...