Scientific Production Faculty

Determination of glyphosate in soil samples using CdTe/CdS quantum dots in capillary electrophoresis



Rodríguez Ávila, José Antonio

2019

Munoz, R., Guevara-Lara, A., Santos, JLM., Miranda, JM., Rodriguez, JA., Determination of glyphosate in soil samples using CdTe/CdS quantum dots in capillary electrophoresis. MICROCHEMICAL JOURNAL, 2019, 146, 582-587.DOI: 10.1016/j.microc.2019.01.059


Abstract


In this work, CdTe/CdS quantum dots were incorporated in a capillary electrophoresis system for the determination of glyphosate in soil samples. Fluorescence spectroscopic evaluation indicates there is an interaction between CdTe/CdS quantum dots and glyphosate, which produces an enhancement of the emission signal as a result of the formation of quantum dots-glyphosate complex. A capillary electrophoresis system for the separation of the complex from the remaining CdTe/CdS quantum dots is described herein. The variables involved in the separation were evaluated and optimized using a central composite design. Signals are elucidated under optimal conditions by calculating the difference in their electrophoretic mobility. The methodology selectivity allows the determination of glyphosate in complex matrices such as soil samples. The proposed method exhibits a linear range from 77.1 to 700?mg?kg?1 with a limit of detection of 25.7?mg?kg?1 and adequate repeatability and reproducibility (%RSD <5.0%). The described methodology was applied to 7 soil samples collected from crop fields in Hidalgo, Mexico, found concentrations varied from 320.6 to 607.7?mg?kg?1.



Research Product




Related articles

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracycli...

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by mu...

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Synthesis and crystal structures of cis-palladium(II) and cis-platinum(II) complexes containing dipy...

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

High-performance liquid magneto-chromatography

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...