Scientific Production Faculty

Flow based determination of Cr(VI) by adsorptive cathodic stripping voltammetry on an immobilized magnetic poly(ionic liquid) modified electrode



Rodríguez Ávila, José Antonio

2018

Ferreira, T.A., Rodríguez, J.A., Galán-Vidal, C.A., Castrillejo, Y., Barrado, E., Talanta, (2018), 183, 172-176. DOI: 10.1016/j.talanta.2018.02.054


Abstract


In this work an electrochemical procedure for Cr(VI) flow based determination in tap water is presented. An AdCSV method was developed using a screen printed electrode modified with magnetic poly(1-allyl-3-methylimidazolium) chloride and the procedure does not require the addition of complexing agents in the solution unlike the methodologies reported so far for Cr(VI) determination. The flow based system is described and the control variables were studied in detail and optimized using a Taguchi parameters design. Under optimal conditions, the electrochemical sensor offered an excellent response to Cr(VI) and the limit of detection estimated from 3? was 0.5?g?L?1 (n?=?3) allowing the analysis of tap water samples. The effect of interfering ions was also investigated below the maximum permissible limits for tap water according to Mexican standards. The presence of the magnetic particles on the sorbent allowed its easy modification on the electrode surface between each determination when removing the magnetic field placed in the wall-jet cell. Finally, the precision of the method was tested with tap water samples using standard addition method for Cr(VI) quantification and the accuracy was evaluated comparing the results with the dyphenylcarbazide method and by analyzing a certified water sample. The method shows good repeatability and reproducibility (%RSD less than 5%) making it feasible for Cr(VI) flow based determination and no significant difference is observed in the results obtained by both methods.



Research Product




Related articles

Evaluation of metal content and its effect on the stability of anthocyanins

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Chemical studies of anthocyanins: A review

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5)-(tris(3,5...

Determination of primary amino acids in wines by high performance liquid magneto-chromatography