Scientific Production Faculty

Size exclusion chromatography (SEC-HPLC) as an alternative to study thrombin inhibition,



Galan Vidal, Carlos Andres

2018

Size exclusion chromatography (SEC-HPLC) as an alternative to study thrombin inhibition, Pérez-Escalante, E., González-Olivares, L.G., Cruz-Guerrero, A.E., Galán-Vidal, C.A., Páez-Hernández, M.E., Álvarez-Romero, G.A., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1074-1075 (2018) 34-38, DOI: 10.1016/j.jchromb.2017.12.037


Abstract


In vitro analysis of anticoagulant compounds with a potential use as antithrombotic drugs, has been traditionally performed using techniques like spectrophotometry, turbidimetry, as well as electrochemical and clinical assays. Although, these techniques have some disadvantages such as: the inability to measure the total biological activity of thrombin, interferences and, sometimes, the quantitative determination of the inhibition ratio is not accurate. In the present work, the conversion of fibrinogen to fibrin was monitored by molecular exclusion chromatography (SEC-HPLC) in three different reaction systems. An inhibition percentage of 43.192.02% was obtained using heparin as an anticoagulant, in addition to the determination of the percentage of heparin bonded to thrombin. This methodology has not been previously described and has high potential for the determination of anticoagulant capacity with higher precision, the determination of thrombin's total biological activity and the quantitative determination of the inhibition ratio



Research Product




Related articles

Study of the Humic Acid-Heavy Metal Interactions and Determination of their Stability Constants....

Synthesis of Zn compounds derived from 1H-benzimidazole-2-ylmethanamine

Predicting the Phase Diagram of a Liquid Crystal Using the Convex Peg Model and the Semiempirical PM...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Cobalt electrodeposition onto highly oriented pyrolytic graphite (HOPG) electrode from ammonium sulfide (HOPG) electrode...

Nucleation and growth of cobalt onto different substrates: Part II. The upd-opd transition onto a go...

Nucleation and growth of cobalt onto different substrates: Part I. Underpotential deposition onto a ...

Influence of the Crystallinity of the Substrate on Kinetic Parameters of Zinc Electrodeposition Proc...

Review of design variables and operating conditions in electrocoagulation.

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS