Scientific Production Faculty

Magnetic solid phase extraction followed by high-performance liquid chromatography for the determination of sulphonamides in milk samples



Ibarra Ortega, Israel S.

2015

I.S. Ibarra, J.M. Miranda, J.A. Rodriguez, C. Nebot, A. Cepeda. Magnetic solid phase extraction followed by high-performance liquid chromatography for the determination of sulphonamides in milk samples. Food Chemistry 157 (2014) 511-517DOI: 10.1016/j.foodchem.2014.02.069


Abstract


A simple and effective method based on magnetic solid-phase extraction combined with high performance liquid chromatography was used for the determination of nine sulphonamides in milk samples. The extraction and cleanup via silica-based magnetic adsorbent dispersion in milk samples followed by the magnetic isolation and desorption of the analytes using NaOH?methanol. Three different magnetic phenyl silica adsorbents were synthesized by varying the molar ratio of phenyltrimethylsilane and tetramethylorthosilicate; these adsorbents were evaluated for sulphonamides retention in terms of their pH and degree of hydrophobicity. The optimal conditions were a pH of 6.0 and a magnetic:sorbent ratio of 2:1. Under optimal conditions, limits of detection ranging from 7 to 14 ?g L?1 were obtained. The method was validated according with the European Commision Decision 2002/657/EC. The proposed method was applied to analyse sulphonamides in 27 milk samples of different brands. Thirteen samples tested were positive for the presence of sulphonamides.



Research Product




Related articles

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Chemical studies of anthocyanins: A review

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Development of a novel composite sensor based on doped pyrrole selective to nitrate ions

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracycli...

Facilitated transport of Hg(II) through novel activated composite membranes