Scientific Production Faculty

New Insights on Naproxen QuantificationUsing Voltammetry and Graphite Electrodes:Development of an Optimized andCompetitive Methodology



Páez Hernández, María Elena

2015

New Insights on Naproxen QuantificationUsing Voltammetry and Graphite Electrodes:Development of an Optimized andCompetitive MethodologyAguilar-Lira, Guadalupe Yoselin,Álvarez-Romero, Giaan Arturo, RojasHernández,Alberto, Páez-Hernández,María Elena, Rodríguez-Ávila JoseAntonio, Romero-Romo, Mario Alberto(2015) ECS Transactions 64 79-89


Abstract


The present work describes a novel, simple and fast electroanalytical methodology for naproxen determination in pharmaceutical formulations. Naproxen?s indirect quantification through an adsorption anodic wave was performed at a graphite bar electrode using differential pulse voltammetry. An anodic current maximum was recorded at a potential of -0.3 V referred to a saturated Ag/AgCl electrode, in the presence of 0.1 mol L-1 phosphates buffer at pH 7 as supporting electrolyte. The naproxen?s oxidation is an irreversible diffusion-controlled process. A calibration plot was done from which a correlation coefficient of 0.990 was obtained with a sensibility of 4.19 0.62 A L g-1, detection and quantification limits of 2.99 and 9.97 g L-1 respectivel



Research Product




Related articles

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Kinetics of Polypyrrole Films Doped with Sulphate Ions Electrodeposited Over Graphite - Epoxy Resin ...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Prevalence and Antimicrobial Resistance Patterns of Salmonella from Different Raw Foods in Mexico

Determination of primary amino acids in wines by high performance liquid magneto-chromatography

Study of the Humic Acid-Heavy Metal Interactions and Determination of their Stability Constants....

Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determinatio...

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracycli...

Metal content evaluation and its effect on the stability of anthocyanins

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...