Scientific Production Faculty

Potentiometric quantification of thebenzoate ion in nonalcoholic beveragesusing a solid electrode modified with apolypyrrole-based selective membrane



Páez Hernández, María Elena

2013

Potentiometric quantification of thebenzoate ion in nonalcoholic beveragesusing a solid electrode modified with apolypyrrole-based selective membraneAguilarLira G.Y., AlvarezRomero G.A.,deJ.LiconaSanchez T., PaezHernandezM.E., GalanVidal C.A., RomeroRomoM.A.(2013) Electroanalysis 25 1519-1527 10.1002/elan.2013000


Abstract


This work presents the results obtained on the construction of a potentiometric ion-selective electrode based on a polypyrrole (PPy) selective membrane to quantify the benzoate ion in nonalcoholic beverages. The electrode modification with benzoate (Benz?1) ion doped-Ppy was carried out under an imposed potential, while the electrosynthesis optimization was undertaken using the modified Simplex method, such that the film?s sensitivity was maximized toward the benzoate ion. The maximum sensitivity recorded was ?52.021.55?mV/decade [Benz?1] using a graphite powder-araldite resin composite electrode. During the modified electrode?s characterization it was found out that the response and drift were relatively short, namely 2?min and 0.4?mV?min?1 respectively, within the 7 to 9 pH range, exhibiting a detection limit of 7×10?4?mol?L?1 and a quantification range of 3×10?3 at 10?1?mol?L?1. Selectivity coefficients were evaluated with the Matched Potential Method obtaining in all cases values much less than 1. The benzoate concentration in commercially available juices and sweetened beverages was evaluated comparing the results obtained with the proposed ion-selective electrode and those of HPLC, the usually accepted technique. A statistical analysis of the results led to the conclusion that there exists no meaningful difference between the results obtained with both techniques, which shows the usefulness of the ion-selective electrode to proceed with the quantification in real samples.



Research Product




Related articles

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5)-(tris(3,5...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Influence of the Cation Nature of the Sulphate Salt on the Electrochemical Synthesis of Sulfate-Dope...

cis-Palladium(II) complexes of derivatives of di-(2-pyridyl)methane: Study of the influence of the b...

Development of a novel nitrate-selective composite sensor based on doped polypyrrole

Magnetic solids in analytical chemistry: A review

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...