Scientific Production Faculty

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropolymerization



Alvarez Romero, Giaan Arturo

2009

Álvarez-Romero G. A., Lozada-Ascencio S. M., Rodríguez-Ávila J. A., Galán-Vidal C. A., Páez-Hernández M. E., Potentiometric Quantification of Saccharin by using a Selective Membrane Formed by Pyrrole Electropolymerization, Food Chemistry, 2009, Vol. 120, Núm . 4, ISSN 0308-8146


Abstract


A selective membrane for direct quantification of saccharinate ion based on a polypyrrole-doped membrane is developed. The membrane is electrochemically prepared using stainless steel as working electrode. Potentiostatic variables for membrane growing such as pyrrole concentration, saccharinate concentration, applied potential and deposition time are optimized in order to maximize sensitivity. The optimized membrane was analytically characterized by means of calibration curves, the detection limit was found to be 3.6 × 10?4 mol L?1 and the quantification limits were found between 5 × 10?4 mol L?1 and over 1 mol L?1. Selectivity of the membrane is evaluated for different inorganic anions, resulting in the following selectivity coefficients: pKSaccharinate,Citrate = 3.4, pKSaccharinate,H2PO4 = 3.4, View the MathML source and View the MathML source.These results demonstrate an adequate performance of the proposed selective polypyrrole membrane so it can be considered as an alternative to traditional analytical methods for the direct quantification of saccharin in diverse samples.



Research Product




Related articles

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Renewable stationary phase liquid magnetochromatography: determining aspartame and its hydrolysis pr...

Prevalence and Antimicrobial Resistance Patterns of Salmonella from Different Raw Foods in Mexico

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Development of a novel nitrate-selective composite sensor based on doped polypyrrole

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Electrochemical and AFM characterization of the electropolymerization of pyrrole over a graphiteepox...

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...