Scientific Production Faculty

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracyclines in milk samples by capillary electrophoresis



Rodríguez Ávila, José Antonio

2011

Ibarra, I.S., Rodriguez, J.A., Miranda, J.M., Vega, M., Barrado, E. Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracyclines in milk samples by capillary electrophoresis, Journal of Chromatography A, 2011, Vol. 1218, p. 2196-2202, ISSN 0021-9673


Abstract


A magnetic solid phase extraction method coupled to capillary electrophoresis is proposed for the determination of tetracycline, oxytetracycline, chlortetracycline and doxycycline in milk samples. Five different magnetic phenyl silica adsorbents covered with magnetite were synthesized by varying the molar ratio of phenyltrimethylsilane and tetramethylorthosilicate; these adsorbents were evaluated in terms of their pH and degree of hydrophobicity for tetracycline retention. The optimal, selected combination of conditions was a pH of 10.0 and a magnetic sorbent ratio of 4:1; under these conditions, the retention capacity ranged from 99.7% to 101.2% for the four tetracyclines analyzed. The elution conditions and initial sample volume of the proposed extraction method were also optimized, and the best results were obtained with 1 × 10?3 M acetic acid in methanol as eluent and a 200 ml of sample volume. Under optimal conditions, average recoveries ranged from 94.2% to 99.8% and the limits of detection ranged from 2 to 9 ?g l?1 for the four tetracyclines. After the proposed method was optimized and validated, 25 milk samples of different brands were analyzed, oxytetracycline residues were detected in five samples, in concentrations ranging from 98 to 213 ?g l?1. Subsequent analysis of positive samples by SPECE and magnetic solid phase extractionHPLC revealed than no significant differences were found from results obtained by the proposed methodology. Thus, the developed magnetic extraction is a robust pre-concentration technique that can be coupled to other analytical methods for the quantitative determination of tetracyclines.



Research Product




Related articles

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Study of the Humic Acid-Heavy Metal Interactions and Determination of their Stability Constants....

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...

Electrochemical and AFM characterization of the electropolymerization of pyrrole over a graphiteepox...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5)-(tris(3,5...

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Metal content evaluation and its effect on the stability of anthocyanins

Influence of the Cation Nature of the Sulphate Salt on the Electrochemical Synthesis of Sulfate-Dope...

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...